Receiving CC messages will control the individual controls, knobs, and switches of the Eternity.

- CC #18 Any value between 0 &amp; 42 sets the subdivision toggle switch to ¼ notes 
    - Any value between 43 &amp; 85 sets the subdivision toggle switch to dotted ⅛ notes
    - Any value between 86 &amp; 127 sets the subdivision toggle switch to ⅛ notes
- CC #19 with any value of 0 thru 127 controls the Mix knob. 0 is the equivalent of having the knob turned completely counter-clockwise (mix turned off) and 127 is like having the knob turned completely clockwise (mix at full volume). Sending a value of 64 is the equivalent of having the knob straight up at noon.
- CC #20 with any value of 0 thru 127 controls the Repeats knob
- CC #21 with any value of 0 thru 127 controls the Filter knob
- CC #22 with any value of 0 thru 127 controls the Cntrl1 knob
- CC #23 
    - Any value between 0 &amp; 63 turns the Bypass switch off
    - Any value between 64 &amp; 127 turns the Bypass switch on
- CC #24 
    - Any value between 0 &amp; 63 turns the Preset switch off
    - Any value between 64 &amp; 127 turns the Preset switch on
- CC #25 any value between 0 &amp; 127 increments the Preset number
- CC #26 any value between 0 &amp; 127 decrements the Preset number
- CC #27 
    - Any value between 0 &amp; 21 activates the Tape delay algorithm
    - Any value between 22 &amp; 44 activates the Digital delay algorithm
    - Any value between 45 &amp; 66 activates the Analog delay algorithm
    - Any value between 67 &amp; 88 activates the Dual delay algorithm
    - Any value between 89 &amp; 110 activates the ESD delay algorithm
    - Any value between 111 &amp; 127 activates the JET Signature delay algorithm
- CC #28 any value between 7 &amp; 127 activates CC Snapshot mode 
    - This takes a snapshot of your current settings and stores it in permanent memory at the appropriate preset location. An example would be to send CC #28 Value 7, this stores a preset in the 7th slot and can be recalled anytime by sending PC #7
- CC #29 
    - Any value between 0 &amp; 63 turns off Kill Dry mode
    - Any value between 64 &amp; 127 turns on Kill Dry mode